Pullboard
A work board that lives in your git repo. Agents pick up the next task, another agent checks it, and you barely explain a thing. Local, open source, no account.
翻譯準備中
尚未偵測到更新。GitHub 發布版本後會顯示在這裡。
個人 GitHub 帳號下公開儲存庫的擁有者可以登入並驗證所有權,自行管理介紹,無需管理員核准。
登入並產生驗證檔案,在 30 分鐘內將其提交至此儲存庫的預設分支。其他分支或分叉儲存庫中的檔案無效。然後在下方檢查檔案,即可無需管理員核准直接管理專案。請保留檔案以維持管理權限。
如需登入,將前往登入頁面。登入後請回到此處,再次點擊所選的驗證按鈕。
在專案資料夾中執行 /nomorevibe verify,即可驗證所有權並自行管理介紹。
一分鐘完成驗證A virtual GPU hall: emulated switches, BMCs and GPUs with fault injection. Apache-2.0.
翻譯準備中
取自儲存庫 README
正在載入完整 README。
檢視完整 README ↗A virtual GPU hall for testing bring-up tooling without hardware. One ground-truth model serves the devices a bring-up tool talks to, with fault injection and technician actions: Redfish BMCs, LLDP tables on Arista (eAPI) and NVIDIA (NVUE) leaves, DCGM exporters, and a minimal NetBox API. Apache-2.0.
pip install simhall turnup-check
simhall serve --golden hall-b & # 127.0.0.1:8900, any token
turnup-check --site hall-b --intent http://127.0.0.1:8900/netbox
reading intent 288 links · 18 nodes · 2 leaves
polling lldp · redfish · dcgm
✓ 286 / 288 links match intent
✓ 17 / 18 nodes reachable, firmware off baseline
✗ mismatch node7 mlx5_3 → leaf4/22
expected leaf4/21
fix move cable one port up
✗ degraded node11 mlx5_5 → leaf4/83 200G
expected leaf4/83 up 400G
fix check transceivers and cable CBL-12-11-05 at leaf4/83 (200G negotiated, intent 400G)
✗ firmware node4 bmc 1.09.2
expected 1.12.0
fix update bmc on node4 to 1.12.0
✗ gpu node14 gpu2 XID 79
expected healthy
fix drain node14 and open an RMA packet for GPU 2
✗ offline node17 redfish unreachable: timeout after 3 s
fix check BMC reachability and credentials for node17
elapsed 3.2 s
The golden hall hall-b is a hall handed over with every light green: five faults of four kinds, one node
each. A technician moves the cable one port up, reseats the degraded one and applies the firmware update, and
the same command prints 288 / 288 links match intent, firmware baseline ok and the two findings that
stay open (the GPU with the XID, the BMC that does not answer) until the trays are replaced:
simhall act '{"kind":"seat_cable","label":"CBL-12-07-03","b_interface":"swp21"}'
simhall act '{"kind":"seat_cable","label":"CBL-12-11-05"}'
simhall act '{"kind":"update_firmware","device":"node4","component":"bmc","version":"1.12.0"}'
Everything here is synthetic: no real hostnames, IPs, serial numbers or topologies. The intent it emits
carries simulated: true, so a simulated run never counts as a real one.
Bring-up tooling is tested on the hardware it is meant to verify, which is the hardware nobody can spare. simhall gives a tool like turnup-check a hall that behaves like the real protocols at every layer, where any fault can be injected, observed through every view at once, and cleared again byte for byte. The test suite of turnup-check runs thousands of random halls and fault sets against it in-process.
pip install simhall # Python 3.12+
pip install git+https://github.com/turnup-dev/simhall # or straight from this repository
From a checkout: pip install -e '.[dev]', then simhall --help. Dependencies: fastapi, uvicorn,
pydantic v2, httpx, pyyaml, click; pynetbox only for simhall seed-netbox (.[netbox]).
| Fault | Observable effect | Expected turnup-check finding |
|---|---|---|
wrong_port(cable, to_device, to_interface) | neighbor appears on the target port, intended port down; node Redfish port shows the target | wrong_port |
missing_link(cable) | intended port down, no neighbor anywhere; node port NoLink | missing_link |
swap_pair(a, b) | the two cables' leaf ports are exchanged | 2 x wrong_port |
link_degraded(cable, 200 | "down") | speed 200G on both ends, or link down with an aging LLDP entry | link_degraded |
unreachable_node(node, timeout | http_500 | refused) | Redfish and/or DCGM answer per mode; links stay up | unreachable_node |
firmware_off_baseline(node, component, version) | the inventory member's version changes | firmware_off_baseline |
gpu_unhealthy, gpu_missing, nvlink_degraded, node_health_warning | DCGM metrics and Redfish health change accordingly | the matching finding |
pdu_outlet_off(node) | BMC and exporter refused, host off, every link down | unreachable_node + missing_link per port |
coolant_leak, partial_redfish, lldp_port_id_mac | leak detectors Critical; FirmwareInventory 404; port ids as MACs | none, by design |
Actions (seat_cable, unseat_cable, power_on, power_off, replace_node, update_firmware,
scan_qr) change the hall the way a technician would and retire the faults they physically resolve.
Faults are applied on top of the base state and clearing one restores the views exactly, in any order.
The complete tables and the rules are in docs/faults.md.
from simhall import HallSpec, Hall, Fault, Action
hall = Hall.generate(HallSpec(site="hall-b", racks=1, nodes_per_rack=18, ports_per_node=16,
leaves_per_rack=2, switch_vendor="nvidia", seed=1))
hall.inject(Fault(kind="wrong_port", cable="CBL-12-07-03", to_device="leaf4", to_interface="swp22"))
hall.lldp_table("leaf4") # what the leaf would say
hall.redfish_tree("node7") # what the BMC would say
hall.act(Action(kind="seat_cable", label="CBL-12-07-03", b_interface="swp21"))
create_app(hall) serves that very object over HTTP, so in-process actions are visible to a tool polling
it. The model, the cabling rule and how state is derived: docs/model.md.
HallSpec, Hall, the cabling rule, base and derived state.hall-b and spec files for your own halls.Apache-2.0. See LICENSE.